PICED Support Files History
This document contains the version history for the following files distributed with PICED:
PICED and Firmware File Versions
PICED Version | Touch Screen and PAC Version | Wiser Firmware Version |
4.4.0 - 4.4.1 | 3.30.0 | - |
4.5.0 | 3.41.0 | 1.5.0 |
4.6.0 - 4.6.1 | 3.42.0 | 1.9.0 |
4.7.0 | 3.43.0 | 1.10.0 |
4.7.1 - 4.7.2 | 3.43.0 | 1.11.0 |
4.8.0 - 4.8.1 | 3.50.0 | 1.15.0 |
4.8.2 - 4.8.3 | 3.51.0 | 1.17.0 |
4.9.0 | 3.60.0 | 1.20.0 |
4.9.1 | 3.60.0 | 1.21.0 |
4.10.0 | 3.61.0 | 1.23.0 |
4.10.1 | 3.62.0 | 1.24.0 |
4.11.0 | 3.80.0 | 1.25.0 |
4.11.1 | 3.80.0 | 1.26.0 |
4.11.2 | 3.80.0 | 1.29.0 |
4.12.0 | 3.80.0 | 1.30.0 |
4.12.1 | 3.80.0 | 1.30.0 |
4.13.0 | 3.80.0 | 1.30.0 |
4.13.1 | 3.80.0 | 1.30.1 |
PAC (and C-Touch & Wiser Logic) Firmware History
Version 3.61
- 20838 Fixed GetCBusGroupAddress and GetCBusLevelAddress
Version 3.60
- 19459 Added basic Unicode support to logic
- 19468 Fixed logic Ord function
- 19456 Improved logic Case statement
Version 3.51
- 18827 Fixed problem with logic timing out
- 18796 Fixed problem with incompatible firmware version causing repeated re-start
- 18634 Fixed SetIBSystemIO
- 18718 Fixed setting Action Selector labels
Version 3.50
- 17647 Add StrToIntDef logic function
- 18427 Added HasChanged logic function
- 18372 Added Power logic function
Version 3.43
- 15786 Fixed rare problem where pressing a button executes function for previous button pressed
- 16545 Made light level reading correspond to PICED and C-Bus ToolKit
- 17005 Prevent group 255 from being controlled by a slider
- 16996 Fixed the display of negative offsets for sunrise and sunset Schedules
- 17117 Fixed Monitor Value in-built System IO
Version 3.42
- 16695, 16543, 16700 Fixed problem with non-lighting applications
- 16564 Default to English for labelling messages
Version 3.41
- 15800 Allow Schedules to be enabled/disabled using in-built System IO
- 15665 Changes to support updated C-Bus Date/Time Application
- 15779 Improved repeat Schedules
- 15853 Added random Schedules
- 15889 Add GetUnitStatus logic function
- 15806 New Logic Function to return C-Bus timer time
- 12634 Allow sending of label commands
- 15882 Added logic function to use Master Unit setting
Version 3.30
- 13351 Problem with use with shutter relay
- 13946 C-Bus commands in logic initialisation section not being sent
- 13706 Updates to HVAC Application usage
- 14019 Heavy C-Bus traffic could cause unit to reset
- 13828 Support SENTEMPB units for monitors
- 13912 Enable group levels were not being restored after power failure
- 11576 Only recall names of used security zones
Version 3.10
- 12630 Support Temperature Broadcast Application
- 12749 Support all application numbers below 128
- 12428 User System IO of type "time" were being cleared when transferred to unit
- 12337, 12338, 12339, 12343 Fixed minor problems with HVAC Application
- 12559 Fixed monitoring light levels
- 10840 Fixed reporting of the Security Application mode
Version 3.0
- 12083 Allow more logic to be run in one scan.
- 10932 Support system IO variables to support :
- 10626 User system IO variables (for logic)
- 6862 Telephony Application
- 6863 Security Application
- 6864 Measurement Application
- 6865 Error Reporting Application
- 6867 Air Conditioning (HVAC) Application
- 11757 Added new Special Functions
- 6647 Don't broadcast time if it has not been set
- 10475 Don't broadcast time near midnight
- 10608 Allow Monitors to be used
- 11288 Add support for Special Days
- 10687 Change Scene status reporting
- 12144 Send non-lighting Application messages to selected Networks
- 12239 Fixed Scene cross-fade
- 9791 Change time on Daylight Savings change
- 9102 SetSceneLevel did not work for default level
Version 2.21
- 8671 Added ability to monitor the PAC usage (% of total scan time used)
- 8769 Added new logic functions
- RunTime function
- ModuleDisabled function
- Module Enabled function
- ConditionStaysTrue function
- TrackGroup procedure
Version 2.5
- 8830 Made the execution of C-Bus commands faster and more consistent.
Version 2.4
- 8599 Fixed the GetCBusTargetLevel and GetCBusRampRate functions.
Version 2.3
- If enabling a module which is already enabled, it no longer cancels any delays in progress.
- Fixed various issues with using ASCII #0 in strings.
Version 2.2
- Fixed problem where a failed transfer of user data could cause the unit to go into a continuous reset loop.
Version 2.1
- Fixed bug with using more than 100 Scenes causing unit to reset after some Scenes were triggered.
- Fixed bug with the last character of a serial (RS232) string being sent twice.
- Fixed bug with timers not operating.
Version 2.0
Black & White C-Touch and C-Touch Spectrum Firmware History
Version 3.80
- 22708 Added support for C-Bus Audio Application
Version 3.62
- 21938 Fixed problem with temperatures in Fahrenheit
- 21852 Fixed problem with touch calibration in Spectrum
Version 3.61
- 20456, 20832 Problems with transferring schedules back to PICED
- 21150 Fixed calibration problem with C-Touch Mark 2 and Spectrum
- 19015 Fixed calibration of C-Touch Spectrum
- 21347 Fixed problem with energy meter totals when using generators
- 21195 Improved average energy calculations
Version 3.60
- 19559 Accumulate energy data for power meters
- 19678 Spectrum proximity sensor setting was being lost during power failure
- 19680 HVAC settings were rounded off during power failure
Version 3.51
- 18803 Fixed problem with use with Shutter Relays
- 18829 Fixed reporting of security panel state
- 18454 Fixed C-Touch Spectrum cleaning page
Version 3.50
- 17445 Added support for C-Touch Spectrum
- 18365 Fixed display of real system IO value decimal points
- 18028 Added support for power meters
- 18112 Added ability to send measurement application messages
- 16998 Added support for Media Transport Control application
- 17646 Added Security Request Special Function
Version 3.42
- 16695, 16543, 16700 Fixed problem with non-lighting applications
- 16564 Default to English for labelling messages
Version 3.40
- 15800 Allow Schedules to be enabled/disabled using in-built System IO
- 15665 Changes to support updated C-Bus Date/Time Application
- 15802 Added in-built system IO for Schedule pulse duration
- 15779 Improved repeat Schedules
- 15853 Added random Schedules
- 15667 Support text alignment in components
Version 3.30
- 13762 Backlight was on slightly even when set to 0%
- 13356 Problem with having Log-out Special Function and Page Link on same Component
- 13351 Problem with use with shutter relay
- 13946 C-Bus commands in logic initialisation section not being sent
- 13706 Updates to HVAC Application usage
- 14554 Invalid System IO properties on a component could cause unit to reset
- 14019 Heavy C-Bus traffic could cause unit to reset
- 13828 Support SENTEMPB units for monitors
- 13912 Enable group levels were not being restored after power failure
- 11576 Only recall names of used security zones
Version 3.10
- 12630 Support Temperature Broadcast Application
- 12749 Support all application numbers below 128
- 12808 Fixed problem with page time-out
- 12767 Six digit passwords did not work
- 12428 User System IO of type "time" were being cleared when transferred to unit
- 12769 Triggering Scenes from the end of a bell press was not working
- 12337, 12338, 12339, 12343 Fixed minor problems with HVAC Application
- 7092 Added Custom Level Indicator option
- 12314 Switch on backlight with alarm snooze
- 12717 Fixed problem with large Scenes with C-Bus Firmware 4.2.00 or earlier
- 12724 Fixed IR Control in C-Touch Mark 1
- 12559 Fixed monitoring light levels
- 10840 Fixed reporting of the Security Application mode
- 13030 C-Touch Mark 1 was resetting when executing very large Scenes
- 7098 Added Selector Component
Version 3.0
This was the first version applicable to C-Touch Mark 2
- 10423 Added logic engine (C-Touch Mark 2 only)
- 7096 Support system IO variables to support :
- 10626 User system IO variables (for logic)
- 10627 editing project properties
- 6862 Telephony Application
- 6863 Security Application
- 6864 Measurement Application
- 6865 Error Reporting Application
- 6867 Air Conditioning (HVAC) Application
- 10946 Support page background colours
- 11757 Added new Special Functions
- 6647 Don't broadcast time if it has not been set
- 10475 Don't broadcast time near midnight
- 7091 Allow passwords to be edited
- 11096 Implement new backlight control algorithm
- 7093 Horizontal Sliders
- 7093 Bar Graph components
- 9820 Bitmap compression to allow larger projects
- 12193 Support concept of an Alarm Page
- 7103 Support multi-sensor
- 7105 Support monitors on remote networks
- 7147 Updated diagnostics page
- 7089 Add support for Special Days
- 7136 Support white fonts
- 10413 Add button to exit PC Interface Mode
- 7106 Extend Schedule editor (day and time types)
- 7137 Show pulse return level
- 7132 Allow edit of Schedule Year
- 10687 Change Scene status indication
- 7133 Don't allow editing of non-lighting application groups in Scenes
- 7120 Bigger Back button on system pages
- 12144 Send non-lighting Application messages to selected Networks
Version 2.22
- 9443 Fixed problem where large projects on some units would cause continual reset
- 9329 Allow backlight to switch completely off
Version 2.21
- 8739 Updated key functions
- added up/down key function
- fixed toggle / dimming scenes
- added ability to use a ramp rate with on/off
- 6736 Updated backlight control to allow the backlight to be on dimly after time-out instead of being completely off.
- 7112 Made alarm sound louder.
- 8488 When selecting a non-existent scene/schedule when there are none would cause the unit to reset.
- 7133 Only allow lighting groups to be edited in the scene editor.
- 7474 Stopped the extra-long press on a scene button opening the scene editor. Should use a special function to edit scenes.
- 7120 Made the "back" button size bigger on the in-built pages.
- 8116 Changed unit addresses to be decimal, rather than hexadecimal
- 8663 Changed group addresses to be decimal, rather than hexadecimal
- 7118 Time was not saved after being changed by a daylight savings special function
Version 2.2
- Fixed problem where a failed transfer of user data could cause the unit to go into a continuous reset loop.
Version 2.1
- Fixed bug with empty Scenes causing the unit to continually reset.
- Fixed bug with using more than 100 Scenes causing unit to reset after some Scenes were triggered.
Version 2.0
- Scenes :
- Added pulses to scenes
- Updated scene editor to show scene names
- Added special function to edit one or all scenes
- Added special function to store scene
- Can now use a component to control all groups in a scene
- Can now show scene status on a component
- Added Scene edit button to the diagnostics page.
- Schedules :
- Schedule time based on repeat time, sunrise or sunset
- Schedule day based on repeat day
- Schedule can execute a Special Function or page link
- Updated editor to show schedule names
- Added ability for Scene groups to be pulsed by a Schedule
- Added Special Function to edit one or all Schedules
- Components (buttons) :
- Can set the ramp rate for a dimmer
- New border styles
- Active status can now show if component is pressed, or is scene is set
- Added nudge up/down
- Ignore press if component has no action ("click through")
- Remote control via C-Bus
- New options for clocks and level indicators
- Access control :
- Now uses access levels
- Added log-in and log-out special functions
- Special Functions and Special Pages :
- Added special function to edit one or all scenes
- Added special function to store scene
- Added Special Function to edit one or all Schedules
- Added Alarm Functions
- Added log-in and log-out special functions
- Backlight now comes on with the alarm.
- When Backlight Set page is open, switched off auto-backlight control
- Other :
- Added daylight savings support
- Page time-out can be set for each page
- Display temperature in C or F
- If start-up page is pressed anywhere but on the "next" button, reset calibration and contrast
- Download a default date/time format to match the PC settings.
- Precautions added to prevent C-Touch project files from running in a PAC or vice versa.
- Firmware will now only run a project file of the correct version.
- Changed backlight operation.
- Improved reliability of communications with computer.
- Fixed "Local SAL" setting
- Fixed bug with "Download Error" page
- When C-Touch detects an error with the configuration data, the error message is now displayed correctly
- Fixed bug with date & time sometimes being reset on power-up
- Broadcast Daylight Savings offset onto C-Bus when time changed
- Fixed bug with MMIs resetting level of groups on remote networks
Version 1.9
- Allow editing of scenes for any Application (not just lighting default).
- Allow more time for power-up before resetting.
Version 1.8
- Changed Preset button long press to off.
- Changed Timer button long press to off.
- Added ability to edit Scenes and Schedules.
- Made changes so it works more reliably as a PCI.
Version 1.7
- Fixed problem with combination of V1.0 monitor and V1.6 firmware.
- Added feature to allow backlight threshold to be adjusted.
- Prevent exit from cleaning mode page when the screen is pressed.
Version 1.6
- Allow Control Application ON and OFF commands to trigger scenes.
- Made dimmer ramp down to level 1 (as for key input units), rather than level 0.
- Added feature to show unit address of last received message (go to Diagnostics page).
- Added display test feature (go to Diagnostics page).
Version 1.5
- Fixed sending commands to remote networks with new bridges.
Version 1.4
- Delay Backlight start-up until power supply has had time to settle.
Version 1.3
- Changed to operate with new C-Touch hardware (PCI chip V4.0).
- Fixed problem with monitors.
- Changed LCD Power Reset to immediately after power-on.
Version 1.2
- Support new LED Backlight.
- Added extra unit information page.
- Fixed problem with C-Bus timers clock resetting the time when pressed.
- Fixed problem with long ramp rates not working properly.
Version 1.1
C-Touch Colour Software History
See PICED "What's New" for general changes. Changes specific to Colour C-Touch and the associated files are listed below.
Version 4.12.1
- 25093 Added DALI List/Profile mapping, various bug fixed
- 26834 Added Web Service server (S+ only)
- 26833 Fixed exception when creating Wiser projects
- 26832 PICED logic error when HTTPGet function cannot retrieve URL
- 26688 Tools password for Wiser not allowing access
- 26849 Error during error report is no timeout page used
Version 4.12.0
- 25093 Added DALI control feature
- 26300 Irrigation number of zones increased
- 24391 Fixed issue with CTC3 file writes
Version 4.11.2
- Update CTC server for compatibility with CTC3 unit
- Update network config utility to support wifi config for CTC3
Version 4.11.1
- 23891 Fixed problem with remote access password being lost
- 23856 Audio Application problem following C-Bus reconnection
- 22687 Extended backlight control
Version 4.11
- 21657 Fixed error message about C-Gate when a logic socket failed
- 22094 Fixed reading of light level from SENPIRIB
- 22660 Fixed problem with C-Bus Discovery happening twice on start-up
- 23464 Improved use of unit without C-Bus connection
Version 4.10
- 20994 Removed C-Bus tab from Project Details Wizard
- 21248 Fixed problem with power failure recovery file being erased if transferring a project twice in quick succession
Version 4.9
- 19633 Some large Scenes would not be forwarded across bridges
- 19589 Show progress of C-Bus scan on start-up
- 19238 Fixed problem with Power Failure Recovery data occasionally being lost on start-up
- 12642 Fixed problem with GetTransportControlData logic function
- 19958 Fixed problem with C-Bus COM port sometimes not connecting
Version 4.8.4
- 19316 CTC sending wrong time details onto C-Bus
Version 4.8.4
- 19316 CTC sending wrong time details onto C-Bus
Version 4.8
- 15880 Show C-Bus Voltage and start-up time on utilities form
- 18523 Components level showing Level instead of % in scene editor
- 18416 Fixed problems with DLL Error 6 occurring
- 18415 Fixed DLL Error 11 occurring on start-up
- 18664 Fixed problem with scene kill from remote networks
Version 4.7.1
- 17526 Fixed editing user system IO
- 17476 Colour C-Touch password (for transfer via Wiser) was being lost
Version 4.6.1
- 16802 Monitors didn't work with SENTEMPB temperature sensors
Version 4.6
- 16466 Fixed problem where changing the time on Colour C-Touch would not send new time to C-Bus
Version 4.5
- Added SlimInterface
- Updated CTC server
- Remove windows device update agent
Version 4.4
- 13720 Editing project details caused C-Bus project to be cleared and hence tags were not available
- 13692 Fixed problem with using C-Bus tags with a space at the end in logic
- 13856 Update C-Bus Module
Version 4.1
- 12876 Added more details for errors with C-Bus Tag file
- 12744 C-Bus Tags are no longer case sensitive in logic
- 12796 Allow for much larger C-Bus Tag file
Version 4.0
- 5703 Add iPod control
- 9898 Allow timers to be up to 18 hours
- 8963 Fix ramp to level 0 behaviour
- 6757 Support Monitors on remote Networks
- 6765 Change the tag mechanism to fix a variety of issues :
- 6634 Lighting Application gets renamed during export
- 8457 Trigger and Enable Applications get renamed during export
- 6461 Invalid characters in tags cause problems
- 8513 Need to have network 254 in a project
- 6408 Can not transfer to a Colour C-Touch if using a shared network drive
- 8637 Duplicate tags cause problems
Version 3.7
- 9171 Fixed bug with using some third party remote controls
- 9082 C-Bus ramp rates were inaccurate when the processor got very busy
- 8743 Improved backlight controls on the Utilities form
- 8657 Sped up the display of the utilities form
- 8891 Sped up closing all forms
- 9198 During the logic initialisation, the "time" was returning a value of -1.
- 9236 Fixed problem with reading multi-sensors with colour C-Touch on remote networks
Version 3.5
- 8496 Fixed using monitors with remote networks.
- 7902 Reduced size of Scene Component form to fit screen
- 7891 Added operating system version info to properties form
- 6751 Added memory information to properties form
- 7905 Hid help buttons
- 7193 Added ability to set DNS IP Address and firewall ports
- 4980 Added ability to display HTML components (web cams etc) - needs update to operating system for this to work
- 8333 Removed buttons allowing adding/editing of C-Bus tags
- 5884 Prevent reset when loading very large projects
- 6750 Display an error message if a project is too large to load
- 7901 Prevent forms from disappearing behind HomeGate
- 8418 Prevent users from modifying logic code
Version 3.3
- Added Re-Start Special Function. A Schedule executing a re-start should be used on ALL projects.
- Fixed the usage of C-Bus time messages
- Added Page Transition effects
- Changes to Log :
- When using "limit file size" option, create a new file at midnight each day.
- Added automatic deletion of old files
- Added more information to log when it starts.
- Added Special Function to allow user to change some of the Project Details.
- Reduced the size of the project XML file to speed up loading and to allow the use of larger projects.
Version 3.2
- Added pop-up editor for all spin-edit controls.
- Fixed bugs with network modeling.
- Hid all help buttons.
- Show a "wait" form when opening external program.
- Added large buttons for setting Schedule time.
- Added edit button for Scene Name.
- Enabled autosave.
- Prevent reset during Schedule Sync and large project load.
- Improved operation of C-Bus connection :
- Show progress during C-Bus connection.
- Show if C-Bus not connected.
- Continuously check for C-Bus connection, and re-connect if needed.
- Fixed bug where Applications not used on the local network didn't work.
Version 2.7
- Save project immediately after any changes are made.
- Disable HTML Component.
- Updated to use new aux processor DLL.
- Improved communications with aux processor.
- Added communications with CTC Server.
- Fixed reception of Trigger Control and Enable Control messages.
- Provided more detailed log message for C-Bus DLL failures.
Transfer Utility Software History
Version 2.16.9
- Add support for new unit types CTC3 & Wiser (white)
Version 2.15.0
- Allow transfer of project with firmware to Wiser
- 19961 Allow more time for transfer of project from CTC to PICED
- 16397 Improved process of transfer of project from CTC to PICED
- Restructured form
- 17748 Fixed operation under Windows 7
- 14691 Fixed operation under Windows Vista
Version 2.9.0
- Removed support for CTC operating system SP1
Version 2.6.0
- Fixes for non-English language support
Version 2.4.0
- 17314 Display non-english project names with ??? rather than apparently random characters
- 17495 Fixed Screen Grab
Version 2.3.3
- 17063 Show current file name in C-Bus unit
- 11293 Improved transfer of projects from units
Version 2.3.0
- Separate CTC firmware transfer from project transfers
- 16437 When uploading a file to a path that doesn't exist the path doesn't get created
Version 2.2.0
- Rewrote utility to suit new requirements
- Added Wiser Support
Slim Interface History
Version 1.4.0
- 16599 Added album listing when artist is selected to work around problem with Squeeze Centre
Version 1.2.0
Media Director History
Version 1.1.0
iPod Server History
Version 1.1.0
- 13097 Include firmware version support for desktop iPort
Version 1.0.0
Windows Media Player Plug-in History
Version 4.0.0
- 10724 Updated to work with windows media player 11
- 10725 plugin not working with Windows media center
- 9518 Fix media player plugin installer
Version 3.7.0
Wiser Firmware History
Version 1.30.1
- Fixed issue with daylight savings affecting schedules when NTP disabled
- Fixed IP address format error when changing the address from the router interface
Version 1.30.0
- Improve string handling memory utilization for ReadClientSocket
- Implement support for PostHTTPData, ReadHTTPPostData, GetHTTPData,
and ReadHTTPData in Logic
- Improve robustness of port forwarding when handling CTCs behind Wiser
- 24738 - tag database error if Schedule with Scene is edited on
Wiser using Adobe Flash UI and then project is retrieved from
unit
- Fix bug that was limiting number of client sockets to 3 rather than 4
- Fix bug that was limiting WriteClientSocket and WriteServerSocket
to 30 byte strings
Version 1.29.0
- 24563 Changes to remote cni/projector/project access would be reset when retrieving project in PICED
- 24331 Fix for clients being unable to reconnect after transparent mode connection
- 24175 Improve robustness in responding to ephemeral client connections
- Fix for regression in opening remote port for CNI mode/toolkit connections
- Fix for regression for widget label edits affecting iPhone/iPad
Version 1.26.0
- 22277 Fixed Monitor issues
- 23663 Use of alternate ports for email POP3/SMTP server
- 23889 CTC Discovery using Wiser in router mode did not work
- 22125 Fixed problem of retrieval of System IO Variable values
- Fixed problem with large projects
Version 1.25
- Added support for C-Bus Audio Application
Version 1.24
- 20516 Save and retrieve latest power metering history upon retrieving project from Wiser
Version 1.23
- 20838 Fixed GetCBusGroupAddress and GetCBusLevelAddress
- 20456, 20832 Problems with transferring schedules back to PICED
- 21347 Fixed problem with energy meter totals when using generators
- 21195 Improved average energy calculations
Version 1.22
- Fix system failure observed when projects with certain configurations and particular number of scenes are used
Version 1.21
- Fixed problem with using project names with three or less letters
Version 1.20
- 19559 Accumulate energy data for power meters
- 16396 Support Discovery using C-Bus IP Utility
- 19354 Handling of Schedules with Pulses
- 19510 Reporting of status of remote scenes
Version 1.17
- 18958 Tamper event not reported
- 18698 Fixed reporting of analog power meter events for internally executed logic
- 18862 Disabled UPNP and adjusted TCP/IP Connection Tracking Timeout values to improve stability
Version 1.15
- 17739 Fixed editing of Start/End Time of Repeat Schedules
- 18047 Fixed SysIO for Measurement App
- 18289 Fixed inability to communicate with devices with ethernet MAC OUI containing non-zero-upper-5-bits
- Support for In-Built System IO for Processor Utilization and Free Memory
- Support for Power Metering and Power History
- 18627 Fixed range for system IO integer and real events
Version 1.11
- 15644 Fixed logic IsWiser function
- 16765 Fixed logic engine socket problem
- 17559 Fixed problem of using null characters with logic sockets
- 17373 Prevent use of overly long names
- 16876 Do a full reset after an external device has used the Wiser CNI
- 17636 Fixed Scene pulse duration and return level
Version 1.10
- Added support for Unicode
- Added ability to edit Function, Location and Widget Names
- Added ability to Edit Scenes and Schedules
- Improved Port Forwarding and Camera Cleanup Support
- Allow use of up to 20 lighting applications
- Added check for compatibility with User Interface
- Fixed e-mail support and performance in logic
- Fixed logic socket problems
- 16788 Fixed HVAC Temperature in-built System IO variable
- 16765 Fixed string in-built system IO in logic
- 16860 Fixed HVAC refresh
- 17008 Fixed sporadically switching into LAN mode
Version 1.9
- 16788 Fixed problem with using HVAC in-built System IO
- 16765 Fixed problem with re-opening server TCP/IP socket
Version 1.8
- 16747 Recalculate sunrise/sunset values independently of whether NTP is enabled or disabled
- 16748 Increase the maximum width of strings in logic to be 50 characters
Version 1.7
- 16720 Fix bug in project upload handling
Version 1.6
- Set default labeling language to English
- Improvements in sunrise/sunset support with NTP synchronization
- Add HVAC plant status event reporting
Version 1.5
- 16546 Add DNS processing to be used when in LAN mode.
- 16558 Add support for sunrise/sunset
- Bugfix for handling of ClientSocketConnected/ServerSocketConnected
- Do not change DLS when transparent mode is used
- 16540 Handle time corrently in logic/scheduling when set via Flash UI
- Improvements of netmask handling
- Issue security status 1 and status 2 request during bootup
Version 1.4
Wiser User Interface History
Version 4.74
- 18719 System IO Date widget is Off by one Day
- 24245 Hide web camera label when text length is zero
- 24337 Replace minutes/seconds time seperator with a colon
- 24341 Schedule time not displayed correctly when negative offset for sunrise/sunset
- 24562 Editing a security widget label caused the label of the widget under it to change
Version 4.70
Version 3.23
- Fixed problems with Power Meter widgets
Version 3.15
- Added energy data widgets
Version 3.11
- Added power meter widgets
Version 3.10
- 17179 Fixed problem with live editing scenes
Version 3.9
- Support for Chinese language
- Updated Tools page:
- Added optional password
- Added ability to edit Function, Location and Widget Names
- Added ability to Edit Scenes and Schedules
- Cosmetic updates
- Additional skins (there are now four skins, with variants of each)
Version 3.5
Version 3.4
Wiser 2 Firmware History
Version 1.31.463